Close Give Feedback
Resene Paints - home page
Follow us on Facebook Follow us on Pinterest Follow us on Instagram Follow us on YouTube

Cost considerations


From the Resene One-Line Specification Manual

It is often difficult to select from a number of apparently equally suitable paint systems to one, which is most economic, and therefore the one, which should be chosen for the job in question. There is only one certain way of making a decision and this is dependent on the volume solids of each paint. Volume solids is expressed as a percentage and means the volume of solid material contained in the paint and that, which forms the dried film of the paint after application. The remainder of the paint evaporates, this being the solvent or thinner necessary for the process of application.

For example, the paint may contain 50% volume solids. This means that 50% of the volume is deposited during application and the remaining 50% evaporates. This also means that to apply a dry film thickness of 50 microns, a wet film thickness of 100 microns must be applied. It is possible to have paints of 100% solids, usually called solventless, and with these there is no volatile content and a dry film thickness will be the same as wet film thickness applied. It is essential that the volume solids of each paint is known together with the cost per litre. These figures permit the easy calculation of the square metreage covered by a litre of paint at the specified film thickness and the cost per square metre. The volume solids of each product dealt with in this manual are available on request from Resene.

Note: 25 microns = 1 thou (or mil).

When it is not clear at first glance which paint will prove the most economic, the foregoing simple calculation provides the answer.

Example:

1
Paint A costs $16.15 per litre, volume solids = 33%
Micron metres/litre = 10 x 33 sq metres = 330 sq metres
 

Cents per micron per sq metre

= 1615 = 4.9 cents
330
 
2
Paint B costs $18.45 per litre, volume solids = 53%
Micron metres/litre = 10 x 53 sq metres = 530 sq metres
  Cents per micron per sq metre = 1845 = 3.5 cents
530

While the cost per litre of paint B is greater, it is in fact actually cheaper, because of its higher volume solids. It is therefore of the utmost importance that volume solids be the only basis for economic acceptance or rejection of similar paints or paint systems. Note that "solids by weight" is a figure that is meaningless and should not be used as a basis of evaluation under any circumstances. Total paint cost for a particular job is given by:

Number of litres required = Total sq metreage to be painted x Dry Film Thickness required
micron metres per litre

Total cost = No. of litres x cost per litre.

In actual practice, theoretical coverage is rarely obtained and an allowance for paint loss must be considered. These factors include the type of surface being painted, type of application, weather conditions, spillage and other wastage, and so on.

Theoretical coverage figures calculated from volume solids should be amended with due allowance for loss and costs calculated from an assessed practical coverage.

Practical Coverage = Theoretical Coverage x Surface Roughness Factor x Application Condition Factor.

Surface roughness factor

  Primer coats Body and finish coats
New smooth steel, pickled steel 0.95 0.98
Blast Cleaned Steel 0.90 0.95
Power Tool Cleaned 0.85 0.90
Blasted - lighted pitted steel 0.85 0.90
Blasted - heavily pitted steel 0.80 0.85
Rough Concrete or Masonry 0.60 0.75

Application condition factor

  All coats
Brush or Roller 0.90
Spray - interior 0.80
Spray - exterior* 0.70

*Subject to wind - if spraying in wind, this factor will be lower than 0.70.

To return to our examples, consider a priming paint of volume solids 54.5% having a theoretical coverage of 10.5 sq metres per litre, giving 50 microns film thickness being applied by spray (no wind) to a heavily pitted blast cleaned steel tank.

Practical coverage = 10.5 x 0.80 x 0.70
= 5.88 sq metres per litre

The above figures are satisfactory for use on profiles up to 75 microns; for higher profiles add 25 microns extra for each 25 microns higher than 75 microns to the dry film thickness to be applied.


Resene One-Line Specifications and Data Sheets
Resene offers clear and simple paint specification guidelines, designed to make specifying the right paint system easier. If in doubt about any aspect of your specification please contact Resene.

View manuals

 

Order online now:
Testpots | Paints | Primers and Sealers | Stains | Clears | Accessories

Get inspired Get inspired ! Subscribe      Get saving Get saving ! Apply for a DIY card

Resene Paints Ltd

Can't find what you're looking for? Ask us!

Resene Paints Ltd   – www.resene.com

Follow us on Facebook Follow us on Pinterest Follow us on Instagram Follow us on YouTube
Videos on how to paint and stain your house
 

Colours shown on this website are a representation only. Please refer to the actual paint or product sample. Resene colour charts, testpots and samples are available for ordering online.   See measurements/conversions for more details on how electronic colour values are achieved.

What's new | Specifiers | Painters | DIYers | Artists | Kids | Sitemap | Home | TOP ⇧